CRANE INDUSTRIAL CHEMICALS -- LIQUID ENZYMES -- 6840-00N053714
=====================  Product Identification  =====================

Product ID:LIQUID ENZYMES
MSDS Date:11/08/1993
FSC:6840
NIIN:00N053714
MSDS Number: BVRBH
=== Responsible Party ===
Company Name:CRANE INDUSTRIAL CHEMICALS
Address:733 W MAIN ST
City:SAN JACINTO
State:CA
ZIP:92383
Country:US
Info Phone Num:909-654-1350
Emergency Phone Num:714-634-5988;800-424-9300(CHEMTREC)
Preparer's Name:STEART HOLYK
CAGE:0AXL9
=== Contractor Identification ===
Company Name:CRANE INDUSTRIAL CHEMICALS
Address:24510 LOS RANCHERIAS
Box:City:HEMET
State:CA
ZIP:92343
Country:US
Phone:714-654-1350
CAGE:0AXL9

=============  Composition/Information on Ingredients  =============

Ingred Name:NON-HAZARDOUS INGREDIENTS
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:SKIN: CONTACT UPON SKIN CAN CAUSE
    SLIGHT IRRITATION. THERE IS ALSO POSSIBILITY OF DEFATTING OF SKIN
    DUE TO REMOVAL OF THE SKIN'S NATURAL OILS. EYES: CONTACT UPON EYES
    CAN CAUSE SLIGHT IRRITATION OF EY ES & EYELIDS. INHAL: FUMES ARE
    GENERALLY CONSIDERED NON-TOXIC BUT CAN CAUSE SLIGHT IRRITATION OF
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: NOSE, NASAL PASSAGES & LUNGS. INGEST:
    WHEN CONCENTRATED SOLUTIONS OF PRODUCT ARE SWALLOWED, IT CAN CAUSE
    SLIGHT IRRITATION OF MOUTH, ESOPHAGUS & STOMACH.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
    OXYGEN/ARTIFICIAL RESPIRATION) . SKIN: FLUSH EXPOSED AREA WITH
    LUKEWARM WATER. EYES: FLUSH EYES WITH COOL WATER FOR AT LEAST 15
    MINUTES. CONSU LT MD IF IRRITATION PERSISTS. INGEST: DO NOT INDUCE
    VOMITING. HAVE PATIENT DRINK LARGE AMOUNTS OF MILK OR WATER &
    CONSULT MD IMMEDIATELY.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SMALL SPILL: FLUSH AREA WITH WATER TO AN
    INDUSTRIAL SEWER LINE. LARGE SPILL: CONTAIN SPILL WITH DIKES OF
    ABSORBENT MATERIALS SUCH AS CLAY, SAND OR VERMICULATE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP THIS MATERIAL AWAY FROM HIGH HEAT
    AND OBSERVE PROPER HOUSEKEEPING PROCEDURES. DO NOT MIX CHEMICALS
    UNLESS INSTRUCTED BY QUALIFIED PERSONNEL.
Other Precautions:CHEMICALS CAN BE HAZARDOUS IF NOT RESPECTED. THE USE
    OF PROPER EQUIPMENT & PROCEDURES FOR HANDLING CHEMICALS ARE NOT
    ONLY OF BENEFIT FOR THEIR OBVIOUS USE, BUT CAN REDUCE THE
    POSSIBILITY OF SERIOUS IN JURY & TIME LOSS ACCIDENTS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE. USE NIOSH/MSHA APPROVED RESPIRATOR
    APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED SAFETY GLASSES .
Other Protective Equipment:NONE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH: CONCENTRATE: 9; 1% SOLN: 8.

==================  Physical/Chemical Properties  ==================

HCC:B3
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.13 (H*2O=1)
pH:SUPDAT
Evaporation Rate & Reference:1.05 (H*2O=1)
Solubility in Water:100% MISCIBLE
Appearance and Odor:MILKY WHITE LIQUID WITH A MINTY ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

====================  Disposal Considerations  ====================

Waste Disposal Methods:THIS MATL IS NOT CONSIDERED HAZ & MAY BE DISP OF
    AS NON-HAZ REFUSE. ALL HAZ MATLS MUST BE SOLIDIFED & DISP OF IN EPA
    APPRVD CLASS ONE FACILITY. WHEN DISP OF CHEMS, CNTCT LOC, STATE &
    FED ENVIRON AGENC IES. KNOW & UNDERSTAND NEC REGS GOVERNING DISP.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.