FEL-PRO CHEMICAL PRODUCTS LP -- C-5A ANTISEIZE, ANTI-SEIZE LUBRICANT, 51011 -- 8030-00-200-3782
=====================  Product Identification  =====================

Product ID:C-5A ANTISEIZE, ANTI-SEIZE LUBRICANT, 51011
MSDS Date:03/18/1997
FSC:8030
NIIN:00-200-3782
Status Code:A
=== Responsible Party ===
Company Name:FEL-PRO CHEMICAL PRODUCTS LP
Address:3412 TOUHY AVE
City:LINCOLNWOOD
State:IL
ZIP:60645
Country:US
Info Phone Num:303-289-5651
Emergency Phone Num:800-424-9300 (CHEMTREC)
Preparer's Name:CATHY GRIFFITH
CAGE:GO402
=== Contractor Identification ===
Company Name:FEL-PRO CHEMICAL PRODUCTS DIV OF FELT PRODUCTS
Address:7450 N MCCORMICK
Box:1205
City:SKOKIE
State:IL
ZIP:60076-8205
Country:US
Phone:303-289-5651
CAGE:GO402
Company Name:FEL-PRO CHEMICAL PRODUCTS LP
Address:3412 WEST TOUHY AVE
Box:City:LINCOLNWOOD
State:IL
ZIP:60645
Country:US
Phone:303-289-5651
CAGE:05VH4

=============  Composition/Information on Ingredients  =============

Ingred Name:GRAPHITE
CAS:7782-42-5
RTECS #:MD9659600
Fraction by Wt: <20%
OSHA PEL:15 MPPCF
ACGIH TLV:2 MG/M3 RDUST

Ingred Name:MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED (SEVERE)
    HEAVY NAPHTHENIC; (HYDROTREATED PETROLEUM DISTILLATES)
CAS:64742-52-5
RTECS #:PY8035001
Fraction by Wt: <25%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:COPPER (SARA 313) (CERCLA)
CAS:7440-50-8
RTECS #:GL5325000
Fraction by Wt: <25%
OSHA PEL:0.1MG/M3 FUME;1 DUST
ACGIH TLV:0.2 MG/M3 FUME
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:DISTILLATES, ACID-TREATED HEAVY NAPHTHENIC; (PETROLEUM
    DISTILLATE)
CAS:64742-18-3
RTECS #:PY8032000
Fraction by Wt: <15%
OSHA PEL:300 PPM
ACGIH TLV:300 PPM

Ingred Name:SILICA, CRYSTALLINE - QUARTZ; (SILICON DIOXIDE
    (ENCAPSULATED))
CAS:14808-60-7
RTECS #:VV7330000
Fraction by Wt: <0.2%
OSHA PEL:0.1 MG/M3 (MFR)
ACGIH TLV:0.1 MG/M3 RDUST

Ingred Name:CALCIUM TALLOWATE; (FATTY ACIDS, TALLOW, CALCIUM SALTS)
CAS:64755-01-7
Fraction by Wt: >3%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED (SEVERE)
    HEAVY PARAFFINIC; (HYDROTREATED HEAVY PARAFFINIC DISTILLATE)
CAS:64742-54-7
RTECS #:PY8035501
Fraction by Wt: >3%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPDAT:NO EXPOS TO FREE RESPIRABLE SILICA IS ANTIC DURING
    NORMAL USE OF THIS PROD. INHAL OF FREE RESPIRABLE (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:SILICA MAY CAUSE SILICOSIS/OTHER SERIOUS DELAYED LUNG
    INJURY. SILICA MAY BE RELS BY GRINDING/MACHINING OF (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:COATED MATLS. USE NIOSH APPRVD DUST/MIST RESP WHEN
    GRINDING/MACHINING COATING/COATED ITEMS. THIS PROD (ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:CONTAINS ENCAPSULATED METAL POWDER WHICH CONTAINS
    COPPER & ZINC. NO EXPOS TO FREE METAL POWDER IS ANTIC (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11:DURING NORMAL APPLICATION OF THIS PROD. METAL POWDER
    MAY BE RELS, HOWEVER, BY GRINDING/MACHINING OF CURED(ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:CMPD/COATED SURF. RPTD/PRLNG OVEREXP TO METAL DUST
    MAY CAUSE METAL-FUME FEVER, METALLIC TASTE & (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:DISCOLORATION OF SKIN & HAIR. REFER TO PROT EQUP
    SECTION FOR APPROP PROT MEASURES.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE CONT:SLIGHTLY IRRIT BUT DOES
    NOT INJURE TISS. AT ELEVATED TEMPS MAY CAUSE IRRIT. SKIN
    CONT:PRLNG/RPTD CONT MAY CAUSE IRRIT. INHAL:AT ELEVATED TEMPS MAY
    CAUSE IRRIT OF RESP TRACT. INHAL OF DU ST AT LEVELS ABOVE RELS MAY
    CAUSE METALLIC/SWEET TASTE, IRRIT OF PHARYNX & POSS ULCERATION W/
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ:IARC
    MONOGRAPHS, VOL 68, 1997:GRP 1. NTP 7TH ANNUAL RPT ON CARCINS,
    1994:ANTIC TO BE CARCIN.
Effects of Overexposure:HLTH HAZ:PERFORATION OF NASAL SEPTUM.
    INGEST:HARMFUL IF SWALLOWED. MOD TOX. IRRIT TO MOUTH, THROAT &
    STOM, W/NAUS. CHRONIC:RPTD & PRLNG INHAL OF GRAPHITE/CARBON DUSTS
    MAY CAUSE PULM FIBROSIS, EMPHYSEM A & PNEUMOCONIOSIS, SEVERITY OF
    THESE EFTS IS GREATLY INFLUENCED BY PRESENCE OF OTHER HARMFUL
    MINERAL DUSTS, (SUPP DATA)
Medical Cond Aggravated by Exposure:PREEXISTING PULMONARY &
    DERMATOLOGICAL DISORDERS MAY BE AGGRAVATED BY EXPOSURE TO HAZARDOUS
    COMPONENTS.

=======================  First Aid Measures  =======================

First Aid:EYES:IMMED FLUSH W/PLENTY OF WATER FOR AT LST 15 MINS. GET
    MED ATTN, IF IRRIT PERSISTS. SKIN:WASH W/SOAP & WATER. GET MED ATTN
    IF IRRIT DEVELS/PERSISTS. INHAL:REMOVE TO FRESH AIR & GET MED ATTN
    IF COU GH/OTHER SYMPS DEVEL. INGEST:DO NOT INDUCE VOMIT. GIVE
    VICTIM GLASS OF WATER/MILK. CALL MD/POIS CTL CTR IMMED. NEVER GIVE
    ANYTHING BY MOUTH TO UNCON PERS. NOTES TO MD:NO INFORMATION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:300F,149C
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP. USE
    WATER TO COOL EXPOS CNTNRS. WATER STREAM DIRECTED INTO FIRE MAY
    CAUSE FROTHING W/SUBSEQUENT SPREAD OF FLAMES.
Unusual Fire/Explosion Hazard:FINELY DIVIDED DUST IN AIR MAY PRESENT
    EXPLO HAZ. PVNT DUST BUILDUP. CLSD CNTNRS MAY RUPTURE/EXPLODE (DUE
    TO PRESS BUILD UP) WHEN EXPOS TO EXTREME HEAT.(SUPDAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:RECLAIM CLEAN MATERIAL. CONTAMINATED MATERIAL
    SHOULD BE SWEPT OR SHOVELED INTO APPROPRIATE WASTE CONTAINER &
    DISPOSED OF I/A/W APPLICABLE FEDERAL, STATE & LOCAL REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID PROLONGED OR REPEATED CONTACT
    W/SKIN. DO NOT TAKE INTERNALLY. FOR INDUSTRIAL USE ONLY. STORE AWAY
    FROM HEAT. KEEP OUT OF THE REACH OF CHILDREN.
Other Precautions:FOLLOW GENERAL INDUSTRIAL SAFETY PRACTICES DURING
    USE. DO NOT REUSE EMPTY CONTAINERS W/OUT COMMERCIAL CLEAN OR
    RECONDITION. FOLLOW ALL MSDS/LABEL PRECAUTIONS EVEN AFTER CONTAINER
    IS EMPTIED.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NORMALLY REQUIRED UNDER GENERAL VENT. IF
    EXPOSURE LEVELS ARE UNKNOWN, IF LEVELS EXCEED TLV/PEL, OR IF
    EFFECTS OCCUR, USE NIOSH APPROVED DUST/MIST RESPIRATOR I/A/W
    APPLICABLE HEALTH & SAFETY REGUL ATIONS & MFR'S RECOMMENDATIONS.
Ventilation:GENERAL VENTILATION USUALLY ADEQUATE.
Protective Gloves:CLOTH OR SYNTHETIC GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . CLEAN CLOTHING TO COVER SKIN.
Work Hygienic Practices:WASH HANDS BEFORE EATING.
Supplemental Safety and Health
EXPLO HAZ:IRRIT &/OR TOX GASES/FUMES MAY BE GENERATED BY THERMAL
    DECOMP/COMBUST. MATLS TO AVOID:PALLADIUM, SELENIUM, MANGANESE,
    MAGNESIUM + POTASSIUM CHLORATE, SODIUM CARBONATE, SULFATES,
    DIBORANE. EF TS OF OVEREXP:MOST NOTABLY CRYSTALLINE SILICA. THIS
    PROD CONTAINS ENCAPSULATED SILICON DIOXIDE (QUARTZ, SILICA). (ING
    8)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>550F,>288C
Vapor Density:HVR/AIR
Spec Gravity:1.3017
Evaporation Rate & Reference:SLOWER THAN BUTYL ACETATE
Solubility in Water:INSOLUBLE
Appearance and Odor:HIGH VISCOSITY, COPPER COLORED PASTE; SLIGHT
    PETROLEUM ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG LEWIS/MINERAL ACIDS. STRONG BASES/OXIDANTS. NITRATES, NITRITES,
    CHLORINATED HYDROCARBONS, CHLORIDES, (SUPP DATA)
Stability Condition to Avoid:PROLONGED EXPOSURE TO HEAT.
Hazardous Decomposition Products:OXIDES OF CARBON. VARIOUS
    HYDROCARBONS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:REVIEW ALL CURRENT FEDERAL, STATE & LOCAL
    REGULATIONS REGARDING HEALTH & DISPOSAL FOR APPROPRIATE DISPOSAL
    PROCEDURES. INCINERATION PREFERRED.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.