SHERWIN-WILLIAMS CO -- PROMAR VARNISH SANDING SEALER, NAVY -- 8010-00N070524
===================== Product Identification =====================
Product ID:PROMAR VARNISH SANDING SEALER, NAVY
MSDS Date:12/11/1995
FSC:8010
NIIN:00N070524
=== Responsible Party ===
Company Name:SHERWIN-WILLIAMS CO
Address:101 PROSPECT AVE NW
City:CLEVELAND
State:OH
ZIP:44115
Country:US
Info Phone Num:216-566-2902
Emergency Phone Num:216-566-2917
CAGE:54636
=== Contractor Identification ===
Company Name:SHERWIN-WILLIAMS CO THE
Address:101 PROSPECT AVE NW
Box:City:CLEVELAND
State:OH
ZIP:44115-1042
Country:US
Phone:800-251-2486/216-566-2242
CAGE:54636
============= Composition/Information on Ingredients =============
Ingred Name:VM & P NAPHTHA VP: 12.00
CAS:64742-89-8
Fraction by Wt: 44%
OSHA PEL:300 PPM (MFR)
ACGIH TLV:300 PPM (MFR)
Ingred Name:SOLVENT NAPHTHA (PETROLEUM) MEDIUM ALIPHATIC; (MINERAL
SPIRITS) VP: 2.00
CAS:64742-88-7
Fraction by Wt: 21%
OSHA PEL:100 PPM (MFR)
ACGIH TLV:100 PPM (MFR)
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TO MIN EXPOS FOLLOW REC FOR PROPER
USE, VENT & PERS PROT EQUIP. ACUTE: IRRIT OF EYES, SKIN & RESP SYS.
MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON &
POSS DEATH. REDNESS & ITCH/BURNIN G SENSATION MAY INDICATE
EYE/EXCESS SKIN EXPOS. HDCH, DIZZ, NAUS & LOSS OF COORD ARE
INDICATIONS OF (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: EXCESS EXPOS TO VAPS/SPRAY MISTS.
CHRONIC: PRLNG OVEREXP TO SOLV INGS MAY CAUSE ADVERSE EFTS TO LIVER
& URINARY SYS. RPTS HAVE ASSOC RPTD & PRLNG OVEREXP TO SOLV W/PERM
BRAIN & NERV SYS DMG. CAL PROP 65: WARNING: THIS PROD CONTAINS A
CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP
WARM AND QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY WITH SOAP AND
WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE. EYES:
FLUSH WI TH LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET
MEDICAL ATTENTION. INGESTION: GET MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:52.0F,11.1C
Lower Limits:0.5%
Upper Limits:6.0%
Extinguishing Media:USE CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZZ ARE
PREFERABLE. WATER MAY BE USED TO COOL CLSD CONTRS TO PVNT PRESS
BUILD-UP & POSS AUT OIGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT.
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLICATION TO HOT SURF REQUIRES SPECIAL
PREC. DURING EMER CNDTNS OV EREXP TO DECOMP PRODS MAY CAUSE HLTH
HAZ. SYMPS MAY NOT BE IMMED APPARENT. OBTAIN MED ATTN.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE ONLY WITH ADEQUATE VENTILATION.
AVOID BREATHING VAPOR AND SPRAY MIST. AVOID CONTACT WITH SKIN AND
EYES.
Other Precautions:THIS COATING MAY CONTAIN MATLS CLASSIFIED AS NUISANCE
PARTICULATES (LISTED "AS DUST" IN INGS SECTION) WHICH MAY BE
PRESENT AT HAZ LEVELS ONLY DURING SANDING/ABRADING OF DRIED FILM.
CONTENTS ARE FLAM. KEEP AWAY FROM HEAT, SPARKS, & OPEN FLAME.
DURING USE & UNTIL ALL VAPS ARE GONE: KEEP AREA VENTD. DO NOT
SMOKE. (SUPDAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF PERS EXPOS CANNOT BE CONTROLLED BELOW APPLIC
LIMS BY VENT, WEAR PROPERLY FITTED ORG VAP/PARTICULATE RESP APPRVD
BY NIOSH/MSHA FOR PROT. WHEN SANDING/ABRADING DRIED FILM, WEAR
DUST/MIST RESP APPRVD BY NIOSH/MSHA FOR DUST WHICH MAY BE
GENERATED FROM THIS PRODUCT, UNDERLYING PAINT, OR THE ABRASIVE.
Ventilation:LOC EXHAUST PREFERABLE. GEN EXHAUST ACCEPTABLE IF EXPOS IS
MAINTAINED BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS 1910.94,
1910.107, 1910.108.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
OTHER PREC: EXTING ALL FLAMES, PILOT LIGHTS & HEATERS. TURN OFF STOVES,
ELEC TOOLS & APPLIANCES, & ANY OTHER SOURCES OF IGNIT. CONSULT EPA
CODE. USE APPRVD BONDING & GROUNDING PROC. KEEP CONTR CLSD WH EN
NOT IN USE. TRANSFER ONLY TO APPRVD CONTRS W/COMPLETE & APPROP
LABELING. DO NOT TAKE INTERNALLY. KEEP OUT(OTHER INFO)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>240F,>116C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.83
VOC Pounds/Gallon:543
VOC Grams/Liter:4.53
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Percent Volatiles by Volume:73
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
RCRA 40 CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINE
APPLIC EPA HAZ WASTE #. INCIN IN APPRVD FACILITY. DO NOT INCIN CLSD
CONTRS. DISP OF I/A/W FED, STATE & LOC REGS REGARDING POLLUTION.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.